Patient Monitor Model: PM8000A 7

Patient Monitor Model: PM8000A 7

Product Application:

Adult/Pediatric/Neonatal/Medicine/Surgery/ Operating Room/ICU/CCU

Product Description

Product Features:

Light & handy

Measurement: ECG/ SpO2/NIBP/HR&PR/Resp

Network: Wire/wireless network & online update

Triplex alarms: Light/Sound (High/medium/low levels adjustable) Electrode Disconnection Alarm (Diagram)

Windows XP Operating System

Easy operation/stable performance

Electrotome/defibrillation tolerance

Restore within 5 seconds after defibrillation

Power Supply: AC & DC Data Storage

Trend diagram/table: 720h

NIBP review: 10000 events

Wave review: 12h

Alarm review: 200 alarm events

Support drug concentration titration analysis

Physical Specification:

Product dimension & weight Equipment: 180mm×380mm×300mm&2kg

Package: 360mm×250 mm×290mm&4kg

Monitor : 7” real color TFT screen ,  Resolution:800*480

Electrical Power : AC: 100 ~ 240V, 50Hz/60Hz ; DC: Built-in rechargeable battery

Product Technique Specification:

ECG

3Leads:     RA, LA, LL

Lead mode:  I, II, III

5 Leads: RA, LA, LL, RL, V

Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V

Resp

Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3Ω

Base Impedance range: 200Ω ~ 4000Ω

Bandwidth: 0.3 ~ 2.5Hz

 

Battery

11.1V 24wh Li-ion battery

2h operating after full charge(one piece)

5min operating after low battery alarm

AC and Drift tolerance

Segment Range:

-2.0mV ~ +2.0mV (accuracy 0.02mV)

Heart/Pulse Rate

Measure range:

Adult 15 ~ 300 bpm Neonatal/Pediatric  15 ~ 350 bpm Accuracy: ±1%      Resolution:        1 bpm

NIBP

Method: Oscillometry

Measure mode: Manual, Auto, STAT Measure

Heart/Pulse Rate

Measure range:

Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm   Accuracy: ±1%       Resolution: 1 bpm

Optional: Temp

Channel 2

Measure & alarm range 0 ~ 50°C Resolution 0.1°C

Accuracy (no sensor) ± 0.1°C (0~50°C

Support heart Pacemaking Analysis

13 Arrhythmia Analysis:

Asystole, V-Fibrillation/Tachycardia, Single/Paired/Multiform PVC, Bigeminy, Trigeminy, Polycardia, P-0N-T, Bradycardia, Leaky-wave, Pacemaker

not captured, Pacemaker failure

SpO2

Measurement range: 0 ~ 100%

Resolution: 1%

Accuracy: 70% ~ 100% ±2%

40% ~ 69%      ±3%

 

IBP (optional)

——

 

 

EtCO(optional)

——

System Inputs & Outputs

NIBP/SpO2/Temp/ECG/IBP Sensor Sockets RJ45 port

Product Standard Package:

Main unit

(7”screen) NIBP

NIBP cuff & tube

ECG cable

SpO2  sensor

Lithium-ion battery

Optional Accessories

Touch screen, Trolley bracket, Hanging bracket, Monitor recorder, Vehicle-mounted power supply